ASW-60F: 50/60 Hz static frequency converter, 15 to 60 kVA

Three-phase 60 Hz outputs, ranging from 208 to 480 V, for factory testing of machines intended for use in foreign power grids.

A machine intended for North America or parts of South America must be tested at the voltage and frequency of the destination power grid before shipment. In a facility powered by 400 V – 50 Hz, a power source is needed that generates 60 Hz at the required voltage and maintains it at a stable level while the machine under test starts motors, inverters, and reactive loads.

The ASW-60F (Artificial Sine Wave) is the static frequency converter from INTECH Automazione Sistemi developed for this application: five sizes ranging from 15 to 60 kVA, with an output voltage selectable via the touch panel between 208 and 480 V.

Benefits

  • Full galvanic isolation between the 50 Hz input power supply and the 60 Hz output
  • Sine wave with total harmonic distortion (THD) from 1.5% to 3.5%
  • Output voltage set via a 7″ color touchscreen
  • 10-second ramp-up
  • Auto-off after 10 minutes at minimum load
  • Transformer and filters with 20% derating

Stable 60 Hz output with an unstable input power supply

The system compensates for frequency fluctuations in the power grid and keeps the output voltage and frequency strictly stable. The 20% derating of the filter components prevents overheating under highly reactive and distorting loads, such as the inverters and rectifiers of the machine under test.

  • “200” Series: 220 – 230 – 240 – 254 – 266 – 277 V / 60 Hz

  • “400” Series: 380 – 400 – 415 – 440 – 460 – 480 V / 60 Hz
  • Twin Load: Two proven machines operating simultaneously
  • Energy meter: consumption, imbalances, and load comparisons (optional)

Simulates foreign power grids, eliminates testing risks

The ideal solution for manufacturing companies that export worldwide, allowing them to power and test machinery in 60 Hz test facilities prior to shipment.

ASW-60F

In summary

  • 50 Hz input, 60 Hz three-phase output
  • Apparent power: 15 / 25 / 30 / 45 / 60 kVA
  • Output from 208 to 480 V, in two ranges
  • THD: 1.5–3.5%
  • ABB ACS580 drive
  • ABB CP607 7″ operator panel

Versions of the ASW-60F

SIZE 1

15 kVA

ASW-60F / 15 kVA

  • Maximum load: 11 kW
  • Stationary dimensions: 1,300 × 1,000 × 700 mm
  • Mobile dimensions: 1,500 × 1,000 × 700 mm
  • Weight: 170 kg

Optional: Opt. 1 · 2 · 3 · 4 · 5

SIZE 2

25 kVA

ASW-60F / 25 kVA

  • Maximum load: 18 kW
  • Stationary dimensions: 1,300 × 1,000 × 700 mm
  • Mobile dimensions: 1,500 × 1,000 × 700 mm
  • Weight: 200 kg

Optional: Opt. 1 · 2 · 3 · 4 · 5

SIZE 3

30 kVA

ASW-60F / 30 kVA

  • Maximum load: 20 kW
  • Stationary dimensions: 1,300 × 1,000 × 700 mm
  • Mobile dimensions: 1,500 × 1,000 × 700 mm
  • Weight: 300 kg

Optional: Opt. 1 · 2 · 3 · 4 · 5

SIZE 4

45 kVA

ASW-60F / 45 kVA

  • Maximum load: 31 kW
  • Dimensions (stationary): 2,100 × 1,000 × 500 mm
  • Weight: 400 kg

Optional: Opt. 4 · 5

SIZE 5

60 kVA

ASW-60F / 60 kVA

  • Maximum power: 42 kW
  • Dimensions (stationary): 2,100 × 1,000 × 500 mm
  • Weight: 560 kg

Optional: Opt. 4 · 5

Optional features available upon request for the ASW-60F

  • Option 1 – 2nd output outlet* 5-pole – 32 A for Twin Load testing (SIZE 1–3)
  • Option 2 – Gamma 200** outlet**, 5-pole – 32 A (208–220–230–254–266–277 V) (SIZE 1–3)
  • Opt. 3 – Mobile system with 4 swivel casters + brakes + pull handles (SIZE 1–3)
  • Opt. 4 – Marine environments: tropicalization and tower-type suction system (all sizes)
  • Opt. 5 – Energy meter: energy monitoring, load imbalances, load comparisons (all sizes)

* During simultaneous testing of two loads, the sum of the currents must not exceed the generator set’s rated current.
** During testing with voltages in the “200” range, the load power must not exceed approximately 40% of the generator set’s power.

Verify the correct solution for your test bench

Master Data
Dimensioning data (optional)